The Case of the Repeat-Blowing Fuse
Every trip starts with a walk of the systems — lights, water, slides — better to catch something wrong in the driveway than six hundred miles down the road. This time, the driveway found it for us. A 15-amp fuse blew the instant it touched the panel. Not eventually — instantly, every single time. The position was labeled “kitchen area overhead LTS,” so that’s where I started looking. Voltage at the fuse socket read a clean 13.25V, so the panel itself was fine — whatever was pulling this fuse d